• Guangzhou Zhuyou Auto Parts Co., Ltd.
    Omar
    The NOx sensorsand high pressure fuel pumps arrived in good condition. We tested one set,works very smooth,no error.
  • Guangzhou Zhuyou Auto Parts Co., Ltd.
    Marcus
    Got the parts, checked a few oxygen sensors. Fitment is perfect, connectors feel solid. Can definitely feel the quality. I'll pass your info to a few mates in the industry.
  • Guangzhou Zhuyou Auto Parts Co., Ltd.
    David
    Just finished testing the O2 sensors you sent last week. No fault codes at all, response is really stable. I can tell the quality is much higher than others. These will move fast. Next order I'lladd NOx sensors as well.
  • Guangzhou Zhuyou Auto Parts Co., Ltd.
    Cassidy
    We got your oxygen sensors installed onthe fleet trucks last week. Fuel mileage is already up by about 5%,and no check engine lights at all. That's exactly what we need. Nodowntime, no headaches, just consistentperformence. We'll be switching the whole fleet over toyour sensors from now on.
  • Guangzhou Zhuyou Auto Parts Co., Ltd.
    Chloe
    Good!Very good and new product it fitted perfectly,I love purchasing parts from this company!!!
  • Guangzhou Zhuyou Auto Parts Co., Ltd.
    Danny
    Good!
  • Guangzhou Zhuyou Auto Parts Co., Ltd.
    Christine
    Price is very good
Contact Person : Suxi
Phone Number : +8613392603375
WhatsApp : +8613392603375

Industrial Oxygen Gas Analyzer Sensor TF-30 Sensor for Reflow Furnaces Ferrite Firing Furnaces Other atmosphere management combustion control applicationsMarine Inert Gas System Control

Place of Origin China guangdong
Brand Name EVOzuRun
Certification CE,RoHS
Model Number TF-30D201 (TF-30 Sensor + DTF-201 Receiver)
Minimum Order Quantity NO MOQ
Price Inquire
Packaging Details Common Package or Personalized Customization Package
Delivery Time Inquire
Payment Terms L/C,D/A,D/P,T/T
Supply Ability Inquire
Product Details
Applications Reflow Furnaces Ferrite Firing Furnaces Other Atmosphere Management And Combustion Control Applications Measuring Principle Zirconia Type Limiting Current Method
OE NO. TF-30D201 (TF-30 Sensor + DTF-201 Receiver) Sensor Element Zirconium Dioxide Pipe
Measuring Range Min. 0–1,000 Ppm To Max. 0–25%; Any Four Ranges Selectable With Fixed Zero Point *Output Range Configurable From 0–10 Ppm To 0–100% Calibration Air-point Plus Up To Three-point Calibration Air One-point Calibration Calibration Via Data Input (during Sensor Replacement)
Analog Output Air-point Plus Up To Three-point Calibration Air One-point Calibration Calibration Via Data Input (during Sensor Replacement) Analog Output;DC 4–20 MA, Non-isolated Output, Load Resistance ≤600 Ω DC 0–1 V / DC 0–5 V / DC 0–10 V, Selectable (non-isolated Ou Sample & Calibration Gas Flow Rate 0.5 L/min
Accuracy ±1% FS;±2% FS Response Time ≤60 Seconds (below 0–1,000 Ppm), ≤30 Seconds (0–1,000 Ppm And Above) (90% Response When Switching Calibration Gas)
Drift ≤±2% FS Per Week Power Supply AC Specification: AC 100–240 V ±10%, 50/60 Hz, 50 VA ;DC Specification: DC 24 V ±10%, 50 W
Contact Input Range Switching (voltage-free Contact) Contact Output Open Collector Output, DC 25 V Max. 50 MA Number Of Contacts: 4 Outputs Selectable Functions: Analyzer Fault / Range Echo-back 1 / Range Echo-back 2 / Range Echo-back 3 / Ready / High Concentration Alarm / Low Concentration Alarm
Range Switching Local Range Switching / Remote Range Switching / Auto Range Switching Output Hold Function Output Hold Value Setting: No Hold* / User-defined Value / Value 5 Seconds Before Fault Occurrence *Output Held During Warm-up And Analyzer Fault
High/Low Concentration Alarm High Alarm: Configurable From 0.0–9,990.0 Ppm Or 0.0–100.0% Low Alarm: Configurable From 0.0–9,990.0 Ppm Or 0.0–100.0% RS-232C Communication Function Transmits Measurement Status, Error Code, Measurement Range, And Measured Value Communication Cable Specification: D-sub 9-pin, Straight Cable
Leave a Message
Product Description

Features

  • Sensors and receiver can be installed at desired locations
  • Lightweight and compact design allows easy integration into various systems
  • No standard gas or reference air required (Calibration can be performed using air-point calibration)
  • Supports low-concentration measurement (minimum range: 0–1,000 ppm)