All Products
-
OmarThe NOx sensorsand high pressure fuel pumps arrived in good condition. We tested one set,works very smooth,no error. -
MarcusGot the parts, checked a few oxygen sensors. Fitment is perfect, connectors feel solid. Can definitely feel the quality. I'll pass your info to a few mates in the industry. -
DavidJust finished testing the O2 sensors you sent last week. No fault codes at all, response is really stable. I can tell the quality is much higher than others. These will move fast. Next order I'lladd NOx sensors as well. -
CassidyWe got your oxygen sensors installed onthe fleet trucks last week. Fuel mileage is already up by about 5%,and no check engine lights at all. That's exactly what we need. Nodowntime, no headaches, just consistentperformence. We'll be switching the whole fleet over toyour sensors from now on. -
ChloeGood!Very good and new product it fitted perfectly,I love purchasing parts from this company!!! -
DannyGood! -
ChristinePrice is very good
TF-SD201R AS-210 Industrial Zirconia Oxygen Analyzer Sensor for Boiler Furnace Kiln Flue Gas Monitoring DTF-201R RX-621310 DTF-201R RX-622310-A RE-210 KX-621020-A421D KX-721045-B/A
Product Details
| Product Name | TF-SD201R AS-210 Zirconia Oxygen Analyzer | Model | Zirconia Oxygen Analyzer |
|---|---|---|---|
| OE NO. | TF-SD201R AS-210 DTF-201R RX-621310 DTF-201R RX-622310-A RE-210 KX-621020-A421D KX-721045-B/A | Applications | Semiconductor Manufacturing Equipment, Atmosphere Measurement In Various N2 Furnaces, Air Separation Units |
| Measuring Principle | Zirconia Type Concentration Cell Method | Measuring Range | 0-5, 10, 25% / −15 To 25, −6 To 10, −3 To 5% |
| Calibration | Air-point Calibration Plus Up To Four Additional Points (Calibration Possible For Each Measurement Range) | Analog Output | DC 4–20 MA, Non-isolated Output, Load Resistance ≤600 Ω DC 0–1 V / DC 0–5 V / DC 0–10 V, Selectable (non-isolated Output) |
| Sample & Calibration Gas Flow Rate | 0.5 L/min | Accuracy/Repeatability | ±1% FS (below 0–1% Range), ±0.5% FS (0–1% Range And Above) |
| Linearity | ±3% FS (below 0–100 Ppm Range), ±2% FS (below 0–1% Range), ±1% FS (0–1% Range And Above) | Response Time | ≤30 Seconds (below 0–1% Range), ≤10 Seconds (0–1% Range And Above) (90% Response When Switching Calibration Gas) |
| Drift | ≤±2% FS Per Week | Power Supply | AC 100–240 V, 50/60 Hz, 50 VA |
| External Dimensions | 96 (W) × 96 (H) × 170 (D) (Receiver) | Contact Input | Range Switching (voltage-free Contact) |
| Highlight | Industrial Zirconia Oxygen Analyzer Sensor,Boiler Furnace Flue Gas Oxygen Sensor,TF-SD201R Oxygen Analyzer Sensor |
||
Product Description
Application:
- Oxidizing combustion flue gas oxygen concentration measurement
-
- Small- and medium-sized boilers
- Small- and medium-sized industrial heating furnaces
- Coke ovens
- Heat treatment furnaces (radiant tube furnaces)
- Reducing combustion flue gas atmosphere concentration measurement
-
- Ceramic kilns (shuttle kilns)
- Ceramic kilns (tunnel kilns)
- Ceramic raw material firing furnaces (rotary kilns)
-
Specification Details Model TF-SD201R (AS-210 Sensor + DTF-201R Receiver) Measuring Principle Zirconia type limiting current method Measuring Range 0–5%, 0–10%, 0–25% / −15 to 25%, −6 to 10%, −3 to 5% Accuracy — Repeatability ±1% FS for 0–5% and negative ranges; ±0.5% FS for 0–10% and 0–25% ranges Accuracy — Linearity ±2% FS for 0–5% and negative ranges; ±1% FS for 0–10% and 0–25% ranges Analog Output — 1st Output DC 4–20 mA, non-isolated output, load resistance ≤600 Ω Analog Output — 2nd Output Selectable DC 0–1 V / DC 0–5 V / DC 0–10 V, non-isolated output Response Time ≤10 seconds (90% response when switching calibration gas) Alarm Display Error codes displayed on receiver Warm-up Time 3 minutes Power Supply AC 100–240 V, 50/60 Hz, 50 VA External Dimensions Receiver: 96 (W) × 96 (H) × 170 (D); unit not specified in the image