• Guangzhou Zhuyou Auto Parts Co., Ltd.
    Omar
    The NOx sensorsand high pressure fuel pumps arrived in good condition. We tested one set,works very smooth,no error.
  • Guangzhou Zhuyou Auto Parts Co., Ltd.
    Marcus
    Got the parts, checked a few oxygen sensors. Fitment is perfect, connectors feel solid. Can definitely feel the quality. I'll pass your info to a few mates in the industry.
  • Guangzhou Zhuyou Auto Parts Co., Ltd.
    David
    Just finished testing the O2 sensors you sent last week. No fault codes at all, response is really stable. I can tell the quality is much higher than others. These will move fast. Next order I'lladd NOx sensors as well.
  • Guangzhou Zhuyou Auto Parts Co., Ltd.
    Cassidy
    We got your oxygen sensors installed onthe fleet trucks last week. Fuel mileage is already up by about 5%,and no check engine lights at all. That's exactly what we need. Nodowntime, no headaches, just consistentperformence. We'll be switching the whole fleet over toyour sensors from now on.
  • Guangzhou Zhuyou Auto Parts Co., Ltd.
    Chloe
    Good!Very good and new product it fitted perfectly,I love purchasing parts from this company!!!
  • Guangzhou Zhuyou Auto Parts Co., Ltd.
    Danny
    Good!
  • Guangzhou Zhuyou Auto Parts Co., Ltd.
    Christine
    Price is very good
Contact Person : Suxi
Phone Number : +8613392603375
WhatsApp : +8613392603375

TF-30D201 Zirconia Oxygen Analyzer for Industrial Semiconductor Atmosphere N2 Furnace Air Separation Unit 741934634 971351824

Place of Origin China guangdong
Brand Name EVOzuRun
Certification CE,RoHS
Model Number Ntron Microx-231
Minimum Order Quantity NO MOQ
Price Inquire
Packaging Details Common Package or Personalized Customization Package
Delivery Time Inquire
Payment Terms T/T,D/P,D/A,L/C
Supply Ability Inquire
Product Details
Product Name TF-30D201 Zirconia Oxygen Analyzer Model Zirconia Oxygen Analyzer
OE NO. TF-30D201 741934634 971351824 Applications Semiconductor Manufacturing Equipment, Atmosphere Measurement In Various N2 Furnaces, Air Separation Units
Measuring Principle Zirconia Type Concentration Cell Method Measuring Range Min. 0–10 Ppm To Max. 0–25%; Any Four Ranges Selectable With Fixed Zero Point *Output Range Configurable From 0–10 Ppm To 0–100%
Calibration Air-point Calibration Plus Up To Four Additional Points (Calibration Possible For Each Measurement Range) Analog Output DC 4–20 MA, Non-isolated Output, Load Resistance ≤600 Ω DC 0–1 V / DC 0–5 V / DC 0–10 V, Selectable (non-isolated Output)
Sample & Calibration Gas Flow Rate 0.5 L/min Accuracy/Repeatability ±1% FS (below 0–1% Range), ±0.5% FS (0–1% Range And Above)
Linearity ±3% FS (below 0–100 Ppm Range), ±2% FS (below 0–1% Range), ±1% FS (0–1% Range And Above) Response Time ≤30 Seconds (below 0–1% Range), ≤10 Seconds (0–1% Range And Above) (90% Response When Switching Calibration Gas)
Drift ≤±2% FS Per Week Power Supply AC Specification: AC 100–240 V ±10%, 50/60 Hz, 50 VA DC Specification: DC 24 V ±10%, 50 W
Contact Input Range Switching (voltage-free Contact) Contact Output Open Collector Output, DC 25 V Max. 50 MA Number Of Contacts: 4 Outputs Selectable Functions: Analyzer Fault / Range Echo-back 1 / Range Echo-back 2 / Range Echo-back 3 / Ready / High Concentration Alarm / Low Concentration Alarm
Range Switching Local Range Switching / Remote Range Switching / Auto Range Switching Output Hold Function Output Hold Value Setting: No Hold* / User-defined Value / Value 5 Seconds Before Fault Occurrence *Output Held During Warm-up And Analyzer Fault
High/Low Concentration Alarm High Alarm: Configurable From 0.0–9,990.0 Ppm Or 0.0–100.0% Low Alarm: Configurable From 0.0–9,990.0 Ppm Or 0.0–100.0% RS-232C Communication Function Transmits Measurement Status, Error Code, Measurement Range, And Measured Value Communication Cable Specification: D-sub 9-pin, Straight Cable
Highlight

Zirconia Oxygen Analyzer for Semiconductor

,

Industrial N2 Furnace Oxygen Analyzer

,

Air Separation Unit Oxygen Analyzer

Leave a Message
Product Description
Specification Details
Model TF-21D201 (TF-21 Sensor + DTF-201 Receiver)
Measuring Principle Zirconia type concentration cell method
Measuring Range Minimum: 0–10 ppm; Maximum: 0–25%. Any four ranges selectable with a fixed zero point. Output range configurable from 0–10 ppm to 0–100%.
Calibration Air-point calibration plus up to four additional points. Calibration available for each measurement range.
Analog Output DC 4–20 mA, non-isolated output, load resistance ≤600 Ω. Selectable DC 0–1 V / DC 0–5 V / DC 0–10 V, non-isolated output.
Sample & Calibration Gas Flow Rate 0.5 L/min
Accuracy — Repeatability ±1% FS for ranges below 0–1%; ±0.5% FS for 0–1% range and above.
Accuracy — Linearity ±3% FS for ranges below 0–100 ppm; ±2% FS for ranges below 0–1%; ±1% FS for 0–1% range and above.
Response Time ≤30 seconds for ranges below 0–1%; ≤10 seconds for 0–1% range and above. Based on 90% response when switching calibration gas.
Drift ≤±2% FS per week
Power Supply AC version: AC 100–240 V ±10%, 50/60 Hz, 50 VA. DC version: DC 24 V ±10%, 50 W.
Contact Input Range switching via voltage-free contact
Contact Output Open collector output, DC 25 V max., 50 mA. Four outputs. Selectable functions: Analyzer fault / Range echo-back 1 / Range echo-back 2 / Range echo-back 3 / Ready / High concentration alarm / Low concentration alarm.
Range Switching Local / Remote / Automatic range switching
Output Hold Function Selectable: No hold / User-defined value / Value recorded 5 seconds before fault occurrence. Output held during warm-up and analyzer fault when hold is enabled.
High/Low Concentration Alarm High and low alarms independently configurable from 0.0–9,990.0 ppm or 0.0–100.0%.
RS-232C Communication Function Transmits measurement status, error code, measurement range, and measured value. Communication cable: D-sub 9-pin, straight cable.