OmarThe NOx sensorsand high pressure fuel pumps arrived in good condition. We tested one set,works very smooth,no error. -
MarcusGot the parts, checked a few oxygen sensors. Fitment is perfect, connectors feel solid. Can definitely feel the quality. I'll pass your info to a few mates in the industry. -
DavidJust finished testing the O2 sensors you sent last week. No fault codes at all, response is really stable. I can tell the quality is much higher than others. These will move fast. Next order I'lladd NOx sensors as well. -
CassidyWe got your oxygen sensors installed onthe fleet trucks last week. Fuel mileage is already up by about 5%,and no check engine lights at all. That's exactly what we need. Nodowntime, no headaches, just consistentperformence. We'll be switching the whole fleet over toyour sensors from now on. -
ChloeGood!Very good and new product it fitted perfectly,I love purchasing parts from this company!!! -
DannyGood! -
ChristinePrice is very good
L Lambda Probe Oxygen Sensor Gas Analyzer L-probe EM2020 103-1513 For Mesa Measuring Chamber MK 2 MK 1
| Purpose | For Replace/repair | Condition | New, 100% Brand New |
|---|---|---|---|
| OE NO. | EM2020 103-1513 | Warranty | 1 Year |
| Type | Oxygen Sensor Gas Analyzer | Car Make | For Mesa |
| Universal Fitment | Yes | Logo/graphic Design | Laser Printing |
| Service | OEM ODM | Package | Common Package Or Personalized Customization Package |
| Chip Material | Imported High-precision Chip | Material | Platinum,High-purity Copper ,Plastic |
Product Details
The ceramic part of the lambda probe (solid electrolyte) has the shape of a tube closed on one side. The surface of the probe ceramic is provided on the inside and outside with a microporous platinum layer (the electrodes), which on the one hand has a decisive influence on the probe characteristics through a catalytic effect and on the other hand serves for contacting. On the part of the probe ceramic on the measuring gas side, there is a firmly adhering, highly porous ceramic layer above the platinum layer. This protective layer prevents the residues in the measuring gas from having an erosive effect on the catalytically active platinum layer. This gives the probe a high long-term stability.
The active probe ceramic (ZrO2) is heated from the inside by a ceramic heating element, so that the temperature of the probe ceramic is kept constant regardless of the measuring gas temperature. The ceramic heating element has a PTC characteristic, which leads to rapid heating and limits the power requirement. The connections of the heating element are completely decoupled from the probe signal voltage (R> = 30M-Ohm).
Technical Data
Applications :
Heating systemsIndustrial processes
process technology
Gas analysis
Heat treatment
Sensing element:
Zirconia tubeInstallation thread:
M 18Measuring range:
21 … 1 … 10-26% O2Response time:
approx. 1 secondMeasuring gas temperature:
<200 ° CMeasuring gas quantity:
approx. 20 – 50 l / hConnection (via 2.3 m cable)
Probe signal: socket
Exit:
0 … 1300 mVClimate:
Storage: -40 … + 100 ° COperation: 0 … + 100 ° C
5 … 95% rel. Moisture, free of condensation
Optional accessories:
Replacement for GA 3.03.1MK1
MK2.1
MK2.0